LED Switch Position Indicators

ncng May 20, 2000

  1. ncng

    ncng TrainBoard Member

    695
    74
    28
    I have been installing LED switch position indicators in my control panels. The problem I am having is that sometimes, not always, both LEDs for a switch are illuminated. I am using the relay in a Tortoise switch machine with a positive input, a negative input, and a single output to the two LEDs. The output is run to the anode side of one LED and the cathode of the other LED. It appears to me that there is leakage backwards through the LEDs. Is this a correct assumption? Is there a way to prevent this problem?


    [This message has been edited by ncng (edited 20 May 2000).]
     
  2. ChrisDante

    ChrisDante TrainBoard Member

    579
    2
    24
    <BLOCKQUOTE>quote:</font><HR>Originally posted by ncng:
    I have been installing LED switch position indicators in my control panels. The problem I am having is that sometimes, not always, both LEDs for a switch are illuminated. I am using the relay in a Tortoise switch machine with a positive input, a negative input, and a single output to the two LEDs. The output is run to the anode side of one LED and the cathode of the other LED. It appears to me that there is leakage backwards through the LEDs. Is this a correct assumption? Is there a way to prevent this problem?


    [This message has been edited by ncng (edited 20 May 2000).]
    <HR></BLOCKQUOTE>
    It sounds like you are using two separate LED's instead of one bi color LED. Is this correct? ( I will assume so). What is the purpose of the relay? I use Tortoise machines, bi-polar DC (I believe that was option 2 in the Tortoise instructions) bi color LED's, SPDT switches, my power supply is 9.5V both + & -, and no relays.

    I need more info.


    ------------------
    When in doubt, empty your magazine.
     
  3. ChrisDante

    ChrisDante TrainBoard Member

    579
    2
    24
    <BLOCKQUOTE>quote:</font><HR>Originally posted by ncng:
    I have been installing LED switch position indicators in my control panels. The problem I am having is that sometimes, not always, both LEDs for a switch are illuminated. I am using the relay in a Tortoise switch machine with a positive input, a negative input, and a single output to the two LEDs. The output is run to the anode side of one LED and the cathode of the other LED. It appears to me that there is leakage backwards through the LEDs. Is this a correct assumption? Is there a way to prevent this problem?


    [This message has been edited by ncng (edited 20 May 2000).]
    <HR></BLOCKQUOTE>
    Here's a thought...
    1. when you have both LEDs lit take a volt meter and find out which way the current is flowing. Do this on one of your switches that are operating correctly as well so you have a good constant.
    2. try reversing one of the LEDs see if that changes anything.

    LOL
     
  4. ncng

    ncng TrainBoard Member

    695
    74
    28
    Yes I am using two separate LEDs not a single bi-color LED. I use SPDT switches with center off. This allows me to leave the switch in the center off position when not changing switch position and still show turnout position. I use one of the built in SPDT relays (pins 5,6 & 7) to control the polarity to the LEDs. I use regulated and filtered 5 VDC to power the LEDs. Each LED has a 270 ohm resistor attached to drop the current to about 2 volts.

    I have verified that the polarity switches and the voltage remains constant when changing the turnout position.
     
  5. ChrisDante

    ChrisDante TrainBoard Member

    579
    2
    24
    You are fast approaching my limit of electrical knowledge.

    But here's another try.

    LEDs should only light when voltage is flowing in one direction. IE if the annode is on side A(side A refers to the way you have them wired) then it will light if the annode is on side B than it will not light. LEDs are current direction sensitive. their illumination is dependendent upon the direction of the current. If both are lighting at the same time check current flow and find one that is working correctly duplicate that wiring onto one that is not working correctly and see if that helps.

    LOL

    ------------------
    When in doubt, empty your magazine.
     
  6. Shaydriver

    Shaydriver TrainBoard Member

    18
    14
    5

    Hello Ncng and ChrisDante !
    Assuming this is DCC, I have another suggestion. I have installed, on my fascia panel, 2 LED's per turnout to indicate direction.
    Simply connect one LED between the turnout points and one rail; then one LED between the points and the other rail, with serial resistors. (or - you really need just one resistor in the common Connection; only one LED is lit at a time) The turnout points acts as an SPDT switch, lighting one of the LED's, indicating direction. As a bonus you will see that the points do make contact with the rails.
    I assume a bipolar LED would work equally well.
    As an example you could mount LED:s together with it's switch, clearly indicating status.
    Regards
    Peter
     
  7. Jimbo20

    Jimbo20 TrainBoard Member

    274
    178
    11
    Hopefully, as this problem was posted nearly 18 years ago, it has been sorted by now?
    Jim
     